★ 4.9 out of 5 from verified customers2,450+ recharges completed in Bengaluru

AC Gas Refilling & Recharge in Bengaluru

Cooling dropped off? Low gas almost always means a micro-leak. We locate and seal the leak first, then recharge your split or inverter AC with the correct weight of R32, R410A, or R22 refrigerant. Backed by a 6-month gas warranty.

  • Nitrogen Leak Test Included
  • Vacuuming & Weighed Charge
  • 6-Month Gas Leak Warranty

Book Gas Refilling

Flat rates · 6-month gas warranty

Or call +91 93538 67510. We never share your number.

Call or WhatsApp on +91 93538 67510

Gas Refill CostStarts at ₹1,350
Recharge Time45–60 Min Doorstep
Gas Warranty6-Month Leak Protection

Refrigerants for all major AC brands

LG air conditioners serviced by Cooling Co
Voltas air conditioners serviced by Cooling Co
Daikin air conditioners serviced by Cooling Co
Samsung air conditioners serviced by Cooling Co
Blue Star air conditioners serviced by Cooling Co
Panasonic air conditioners serviced by Cooling Co
Godrej air conditioners serviced by Cooling Co
Haier air conditioners serviced by Cooling Co
Whirlpool air conditioners serviced by Cooling Co
Bosch air conditioners serviced by Cooling Co
Hitachi
& more

Brand names are shown to indicate compatibility only.

The Process

How Our Gas Refilling Works

A scientific, multi-step process that guarantees you get a full, leak-free gas recharge.

1

Nitrogen Leak Test

We charge the system with nitrogen gas to locate micro-cracks in the copper coils. We seal the leak with copper-brazing.

2

Deep Vacuuming

We connect a vacuum pump to draw out all air, moisture, and non-condensables from the lines, preventing compressor blockage.

3

Weighed Charge

We weigh the gas cylinder on a digital scale, charging the exact refrigerant quantity (R32/R410A) specified by the manufacturer.

4

Superheat Test

We verify suction pressures and operating current draws to confirm stable cooling cycles and prevent compressor overload.

Transparent Pricing

Upfront Rate Card

Flat, published prices with no hidden charges. You approve the quote before any work begins.

ServicePrice (INR)
AC gas refill & recharge (Split, R32)₹1,499
Gas top-up (partial charge)₹1,350
Leak fix + full recharge (R410A)₹2,499
Foam & power-jet AC service (Split)₹700
Anti-rust deep-clean AC service₹999

*Prices are base costs. Full weighed gas refilling starts at ₹1,499 (R32 gas). The final quote is provided after nitrogen pressure testing isolates leaks.

Gas Refilling at a Glance

Starting Price
₹1,350
Service Time
45–60 min
Gas Warranty
6 Months
Covered Gases
R32, R410A, R22

Q.Why does my AC leak refrigerant gas?

Refrigerant flows under high pressure. Thermal expansion and vibration cause friction on copper coils, causing micro-cracks over time. Low gas almost always means a leak exists.

Q.Why is vacuuming critical before refilling gas?

Moisture inside lines acts as a contaminant, causing acids that damage compressor windings. Deep vacuuming extracts all air and moisture to keep lines pure.

Cooling Co technician checking AC refrigerant pressures with manifold gauges in Bengaluru
Done Right

The Standards Behind Our Gas Recharging

Filling gas without sealing leaks is a waste of money. Here are our gas recharging standards.

"According to our Head Technician Rahul, 80% of AC cooling failures in Bengaluru are due to unsealed micro-leaks or blocked airways. This is why we mandate rigorous pressure testing and deep coil sanitation over simple gas top-ups."

Nitrogen Leak Test

We pressurize lines with nitrogen gas up to 350 PSI to locate micro-cracks before refilling.

Deep Line Vacuuming

We vacuum lines to 500 microns to draw out all air and moisture before recharging.

Weighed Charging Only

We weigh the gas cylinder on a digital scale to charge the exact manufacturer-specified weight.

6-Month Gas Warranty

If gas leaks from any joint we worked on within 6 months, we seal it and recharge it for free.

Answers

Gas Refilling FAQs

Straight answers to what Bengaluru homeowners ask about AC gas recharge.

Signs of low gas include weak cooling airflow, the compressor running continuously without cycling off, and ice forming on the thin brass copper valves of the outdoor unit. In most cases, low gas is caused by a copper joint micro-leak.

Refrigerant gases operate under very high pressures. If you refill gas without testing and sealing the leakage points, the new gas will escape within days or weeks. Nitrogen testing uses high pressure to locate the exact leak points so they can be brazed closed first.

We always charge refrigerant gas by weight using a digital scale, matching the exact grams specified on your AC manufacturer's sticker. Gauging solely by pressure is inaccurate because gas pressure changes with outdoor temperatures.

We provide a 6-month leak warranty on all full gas recharges. If the refrigerant level drops or leaks from any braze joint we worked on within 6 months, we will return, locate the leak, and recharge it at zero cost to you.

We supply and charge all residential refrigerant gases: R32 (common in modern inverter ACs), R410A, and R22 (found in older split and window models). We carry pure, high-grade gas cylinders.

R32 is classified as mildly flammable. Our technicians are trained to handle R32 safely: they perform deep vacuuming to clear oxygen from lines and verify no open sparks or flames are present during brazing or cylinder connections.

No, leak repair brazing is billed separately based on the number of copper joints requiring welding. Our basic gas refilling charge covers the vacuuming, pressure gauge monitoring, and weighed refrigerant gas charging.

AC Not Cooling? Book Weighed Gas Refill.

Includes nitrogen testing and deep line vacuuming. Backed by our 6-month leak warranty. Starting at just ₹1,499.